Heating System

Lowers Energy Usage by 40%


A 40% reduction in energy usage, better temperature control and uniform heat were key deliverables for a new, low voltage heating solution implemented at British Bakels by Inditherm plc.

British Bakelsmanufacture and distribute a wide range of ingredients, some of whichare tailor made for industrial and in-store bakeries, whilst others are specifically developed for the craft and foodservice sectors. The ingredient most widely used in their production process is glucose, which is extremely viscous and needs warmth to be applied to enable it toflow. Inditherm’s brief was to provide heating and insulation to two tanks containing 30,000 litres of glucose, maintaining the temperatureof the product at 56°C, so it would flow easily and quickly through the production process.

Inditherm, who are based in South Yorkshire, designed a custom made heating system using their patented, low voltage carbon polymer technology. To achieve the target temperature throughout each tank, two Inditherm pads were wrapped around the base ofthe tanks in two circumferential bands, each approximately 10 metres long and 1metre high. Additional tailor-made pads were fitted to the conical base of the tanks to provide low level heating. The fabric-likequalities of the Inditherm’s polymer allow it to be fitted around almost any shape, making it suitable for heating complicated shapes, suchas pumps, or larger areas, such as tanks.

The Inditherm heating pads were then thermally insulated with mineral wool and over-clad with profiled plastisol to provide external protection. To control thetemperature of the tanks, Inditherm provided a bespoke control system,allowing British Bakels to set the optimum temperature for bulk glucose storage. This, together with the introduction of a controlling thermostat and high and low temperature thermostats, ensured that the produce would not drop in temperature, over-heat, or suffer from localisedhot spots.

Since the installation, British Bakels have seen the energy usage from these tanks reduce by 40%, compared to the energyusage consumed when using the traditional method of trace heating. Inaddition, the uniform heating profile of Inditherm ensures no hot spots are generated, which was experienced when previously using trace heating,

Commenting on the installation, Nick Luxemburg, Engineering Manager, British Bakels, said, “Inditherm has provided us with a reliable, low energy usage heating system which meets our criteria of maintaining the glucose in the tanks at a temperature that maximises production efficiency. Following the success of this installation, we have also used Inditherm low voltage systems to heat over 150metres of process pipe containing a variety of products”.

Inditherm plc develop and manufacture heating solutions for markets as diverse as foodprocessing, chemicals, pharmaceuticals, oil & gas, utilities, medical, construction and sport.



Inditherm plc
Houndhill Park
Bolton Road Rotherham
S63 7LG
United Kingdom
tel: +44-1709-761000
fax: +44-1709-761066

Speed Link Info Service
Request more information by e-mail

Reader Service No. Reader Number Email Address
14209